1. The voltage used by this equipment must meet the national grid power supply standards and use requirements.
2. This equipment preferred lifting lifting method, when need to carry to ensure that the vertical translation way, shall not be tilted, impact and violent vibration, otherwise it will lead to the furnace refractory bricks and furnace roof loose or fall off affect durability, etc..
3. The natural gas, liquefied gas and other fuels used in this equipment must comply with the national requirements specifications.
4. Please check whether the gas is within the range of 8kpa-10kpa before use, and the compressed air regulation is >0.5MPA.
5, the limit temperature of this equipment is <1200 ° in <800 ° cool furnace ignition must open all the doors, open the main burner combustion chamber temperature <700 ° shall not close all the doors, in order to prevent the occurrence of explosive combustion accidents.
"Maintenance is more important than repair, and repair is more important than purchase." Correct use and maintenance are necessary guarantees to extend the life of this equipment.
At the same time, please read this manual carefully before installation and use. Strictly follow the requirements of the manual for installation, use and maintenance to avoid accidents and unnecessary economic losses due to operating errors.